Test Code F822B Hemophilia A F8 Gene, Intron 22 Inversion Known Mutation, Whole Blood
Useful For
First-tier molecular testing for male patients affected with severe hemophilia A, when a familial intron 22 inversion has been previously identified
Determining hemophilia A carrier status for at-risk female patients, ie, individuals with a family history of severe hemophilia A due to F8 intron 22 inversion
Disease States
- Hemophilia A
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
MATCC | Maternal Cell Contamination, B | Yes | No |
Testing Algorithm
Maternal cell contamination testing will be performed for all cord blood specimens. A maternal whole blood sample with an order for MATCC / Maternal Cell Contamination, Molecular Analysis, Blood is required to perform this test. See Additional Testing Requirements.
The following algorithms are available:
Special Instructions
Reporting Name
HA F8 Intron 22 Inversion KM, BSpecimen Type
Whole bloodOrdering Guidance
If a familial variant has not been identified in a severely affected hemophilia A patient, order F8INV / Hemophilia A F8 Gene, Intron 1 and 22 Inversion Mutation Analysis, Whole Blood.
For evaluation of a patient with bleeding symptoms and no known personal history of a bleeding disorder consider ALBLD / Bleeding Diathesis Profile, Limited, Plasma or the specific factor assays.
Additional Testing Requirements
Due to the complexity of testing non-peripheral blood, consultation with the laboratory is required for all cord blood samples. Order this test on the cord blood specimen (only 1 specimen tube required) and order MATCC / Maternal Cell Contamination, Molecular Analysis, Blood on the maternal specimen.
Necessary Information
Hemophilia A Patient Information (T712) is required. Testing may proceed without the patient information, however, the information aids in providing a more thorough interpretation. Ordering providers are strongly encouraged to fill out the form and send with the specimen.
Specimen Required
Patient Preparation: A previous bone marrow transplant from an allogenic donor will interfere with testing. Call 800-533-1710 for instructions for testing patients who have received a bone marrow transplant.
Container/Tube:
Preferred: Lavender top (EDTA)
Acceptable: Yellow top (ACD) or blue top (3.2% sodium citrate)
Specimen Volume: 4 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send whole blood specimen in original tube. Do not aliquot.
Specimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Whole blood | Ambient (preferred) | 7 days | |
Frozen | 7 days | ||
Refrigerated | 7 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Genetics Test Information
This test detects the intron 22 inversion within the F8 gene. The intron 22 inversion variant accounts for approximately 45% of variants associated with severe hemophilia A.
Intron 22 inversion known variant analysis can only be performed for individuals when an intron 22 inversion has already been identified in the family. For testing options, see Ordering Guidance.
Clinical Information
Hemophilia A (HA) is caused by a deficiency of clotting factor VIII (FVIII). HA is an X-linked recessive bleeding disorder that affects approximately 1 in 5000 male individuals. Male patients are typically affected with bleeding symptoms, whereas female carriers generally do not have bleeding symptoms but are at risk of having affected sons. Rarely, approximately 10% of female carriers have FVIII activity levels below 35% and are at risk for bleeding.
Bleeding, the most common clinical symptom in individuals with HA, correlates with FVIII activity levels. FVIII activity levels below 1% are associated with severe disease, 1% to 5% activity with moderate disease, and 5% to 40% with mild disease. In male patients with severe deficiency, spontaneous bleeding may occur. In individuals with mild HA, bleeding may occur only after surgery or trauma.
FVIII is encoded by the factor VIII (F8) gene. Approximately 98% of patients with a diagnosis of HA are found to have a variant in F8 (ie, intron 1 and 22 inversions, point mutations, insertions, and deletions). The intron 22 inversion variants account for approximately 45% of variants associated with severe HA. These inversions are typically not identified in patients with mild or moderate HA.
Intron 22 inversion known variant analysis is only recommended for individuals when an intron 22 inversion has already been identified in the family.
If a familial mutation has not been identified in a severely affected HA patient, the F8 gene intron 1 and 22 inversion analysis (F8INV / Hemophilia A F8 Gene, Intron 1 and 22 Inversion Mutation Analysis, Whole Blood) should be ordered.
If the intron 22 inversion analysis is negative, the tested individual has not inherited the familial mutation.
It is recommended that the F8 variant be confirmed in the affected male patient or obligate female carrier prior to testing at-risk individuals. Affected male patients are identified by FVIII activity (F8A / Coagulation Factor VIII Activity Assay, Plasma) and clinical evaluation, while obligate female carriers are identified by family history assessment. If the intron inversion assays do not detect an inversion in these individuals, additional analysis (ie, F8 sequencing) may be able to identify the familial variant. Of note, not all women with an affected son are germline carriers of a F8 variant, as de novo variants in F8 do occur. Approximately 20% of mothers of isolated cases do not have an identifiable germline F8 variant. Importantly, there is a small risk for recurrence even when the familial F8 variant is not identified in the mother of the affected patient due to the possibility of germline mosaicism.
Reference Values
An interpretive report will be provided.
Interpretation
The interpretive report will include assay information, background information, and conclusions based on the test results.
Cautions
Obtaining a medical genetics or hematology (coagulation) consultation prior to ordering is advisable. Consultations with the Mayo Clinic Special Coagulation Clinic, Molecular Hematopathology Laboratory, or Thrombophilia Center are available for DNA diagnosis cases. This may be especially helpful in complex cases or in situations where the diagnosis is atypical or uncertain.
Intron 22 inversion known variant analysis is only recommended for individuals when an intron 22 inversion has already been identified in the family.
This assay detects only F8 intron 22 inversion variants. Thus, a negative result does not exclude the presence of other variants in F8.
The intron 22 inversion variant targeted by this assay is found in approximately 45% of individuals with severe hemophilia A; if an intron 22 inversion has not been already identified in the family, the assay may be uninformative.
Test results should be interpreted in the context of clinical findings, family history, and other laboratory data. Errors in the interpretation of results may occur if the information provided is inaccurate or incomplete.
Method Description
Genomic DNA from whole blood or cord blood is digested with restriction enzyme, ligated with T4 DNA ligase, and amplified by polymerase chain reaction with primers specific for the F8 intron 22 inversion mutations.(Rosetti LC, Radic CP, Larripa IB, De Brasi CD: Developing a new generation of tests for genotyping hemophilia-causative rearrangements involving int22h and int1h hotspots in the factor VIII gene. J Thromb Haemost 2008;6:830-836; Meijer P, Verbruggen, Spannagi M: Clotting factors and inhibitors: Assays and interpretation. In: Kottke-Marchant K, ed. Laboratory Hematology Practice. Wiley Blackwell Publishing; 2012: 435-446)
Day(s) Performed
Weekly
Report Available
14 to 21 daysSpecimen Retention Time
Whole blood: 2 weeks; DNA: Indefinitely, from New York State: 90 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
81403
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
F822B | HA F8 Intron 22 Inversion KM, B | 91679-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
35139 | HA F8 Int22 KM Reason for Referral | 42349-1 |
35007 | HA F8 Intron 22 Inversion KM, B | 91679-1 |
35008 | F822B Interpretation | 69047-9 |
35009 | HA F8 Int22 KM Reviewed By | 18771-6 |
Method Name
Inverse Shifting-Polymerase Chain Reaction (IS-PCR)
Forms
1. Hemophilia A Patient Information (T712) is required.
2. New York Clients-Informed consent is required. Document on the request form or electronic order that a copy is on file. The following documents are available:
-Informed Consent for Genetic Testing (T576)
-Informed Consent for Genetic Testing-Spanish (T826)
3. If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.