Test Code LAB1371 Homocysteine, Plasma

Additional Codes

Test Name in EPIC EPIC Test Code Mnemonic
HOMOCYSTEINE LAB1371 HMCYS

 

Methodology

Chemiluminescent Microparticle Immunoassay (CMIA)

Specimen Requirements

Specimen Type: Plasma

Container/Tube: Lavender top (EDTA)

Specimen Volume: 0.5 mL

Specimen Minimum Volume: 0.2 mL

Collection Instructions: Spin down within 1 hour of draw and promptly separate plasma from cells.

Additional Information:

1. Hemolyzed specimen is not acceptable.

2. Place specimen immediately on wet ice after draw.

3. No add-ons permitted.

Specimen Transport Temperature

Refrigerate 5 days/Frozen OK/Ambient NO

Day(s) Test Set Up

Monday through Sunday

Performing Laboratory

Chemistry-

SMDC Clinical Lab

Test Classification and CPT Coding

83090

Reference Values

5-15 µmol/L