Test Code LAB1371 Homocysteine, Plasma
Additional Codes
Test Name in EPIC | EPIC Test Code | Mnemonic |
---|---|---|
HOMOCYSTEINE | LAB1371 | HMCYS |
Methodology
Chemiluminescent Microparticle Immunoassay (CMIA)
Specimen Requirements
Specimen Type: Plasma
Container/Tube: Lavender top (EDTA)
Specimen Volume: 0.5 mL
Specimen Minimum Volume: 0.2 mL
Collection Instructions: Spin down within 1 hour of draw and promptly separate plasma from cells.
Additional Information:
1. Hemolyzed specimen is not acceptable.
2. Place specimen immediately on wet ice after draw.
3. No add-ons permitted.
Specimen Transport Temperature
Refrigerate 5 days/Frozen OK/Ambient NO
Day(s) Test Set Up
Monday through Sunday
Performing Laboratory
Chemistry-
SMDC Clinical Lab
Test Classification and CPT Coding
83090
Reference Values
5-15 µmol/L