Sign in →

Test Code LAB3979 RNP Antibodies, IgG, Serum

Additional Codes

 

Test Name in EPIC EPIC Test Code Mnemonic Mayo Test ID
AUTOANTIBODIES TO U1RNP LAB3979 U1RNP RNP

 

Reporting Name

RNP Ab, IgG, S

Useful For

Evaluating patients with signs and symptoms of a connective tissue disease in whom the test for antinuclear antibodies is positive

 

Testing for ribonucleoprotein particle antibodies is not useful in patients without demonstrable antinuclear antibodies.

Testing Algorithm

For more information see Connective Tissue Disease Cascade.

Method Name

Multiplex Flow Immunoassay

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.35 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK

Special Instructions

Reference Values

<1.0 U (negative)

≥1.0 U (positive)

Reference values apply to all ages.

Day(s) Performed

Monday through Saturday

CPT Code Information

86235

LOINC Code Information

Test ID Test Order Name Order LOINC Value
RNP RNP Ab, IgG, S 29958-6

 

Result ID Test Result Name Result LOINC Value
RNP RNP Ab, IgG, S 29958-6

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

Clinical Information

Antibodies to U1 ribonucleoprotein particle (U1-RNP) are central to the diagnosis of mixed connective tissue disease and are also associated with other antinuclear antibody (ANA)-associated connective tissue diseases (CTDs) such as systemic lupus erythematosus, systemic sclerosis, undifferentiated CTD, and CTD overlap syndromes.(1-5) Immunologic characterization studies suggest that anti-U1RNP antibodies are directed toward both discontinuous and linear epitopes that are either contained in the protein sequence or are post-translationally modified. These antibodies mainly target the RNP68 or RNP70, RNPA (33 kD), and occasionally RNPC (22 kD) proteins.(4-9)

 

Originally described by Mattioli et al (3) by immunodiffusion assay using calf thymus extract, current solid-phase immunoassays now use diverse analytes (purified or recombinant proteins, synthetic peptides of dominant epitopes) of the 3 main proteins (RNP68 or RNP70, RNPA, and RNPC) either singly or in any of the various combinations.(4-10) Because of the use of these different antigens and combinations thereof, the nomenclature, reporting, and interpretation of anti-U1RNP antibodies remain obscure.(10) In the absence of standardized nomenclature for anti-U1-RNP antibody assays, familiarity of the analytes in specific assays and use of Hep-2 substrate by indirect immunofluorescence assay for ANA are required for appropriate interpretation. In addition, low level anti-U1-RNP antibodies in the absence of ANA have a low predictive value for ANA-CTD. The U1-RNP antibody test offered by Mayo Clinic detects antibodies to both RNP68 and RNPA proteins. Combined response is more sensitive and less specific than assays to the Sm (Smith)/RNP.(10)

 

For more information see Connective Tissue Disease Cascade.

Interpretation

A positive result for anti-ribonucleoprotein particle 68/A (RNP68/A) antibodies in association with positivity of antinuclear antibodies may be consistent with a diagnosis of connective tissue disease.

Cautions

The U1 ribonucleoprotein particle (RNP) 68/A antibody is more sensitive than the Sm (Smith)/RNP antibody test. Low positive results (≤4.0 U) without an associated positive antinuclear antibodies by indirect immunofluorescence assay should be interpreted with caution.

Method Description

Recombinant ribonucleoprotein particle (RNP)-68 and RNP-A antigens are bound to polystyrene microspheres, which are impregnated with fluorescent dyes to create a unique fluorescent signature. RNP antibodies, if present in diluted serum, bind to the RNP antigens on the microspheres. The microspheres are washed to remove extraneous serum proteins. Phycoerythrin (PE)-conjugated antihuman IgG antibody is then added to detect IgG anti-RNP bound to the microspheres. The microspheres are washed to remove unbound conjugate, and bound conjugate is detected by laser photometry. A primary laser reveals the fluorescent signature of each microsphere to distinguish it from microspheres that are labeled with other antigens, and a secondary laser reveals the level of PE fluorescence associated with each microsphere. Results are calculated by comparing the median fluorescence response for RNP microspheres to a 4-point calibration curve.(Package insert: Bioplex 2200 ANA Screen. Bio-Rad Laboratories; 02/2019)

Report Available

1 to 3 days

Specimen Retention Time

14 days