Sign in →

Test Code LAB5008 Lyme Disease Screen, Serum

Additional Codes

Test Name in EPIC EPIC Test Code Mnemonic
LYME DISEASE SCR LAB5008 LYMES

 

Methodology

Chemiluminescence Immunoassay (CLIA)

Specimen Requirements

Specimen Type: Serum

Container/Tube: Serum gel

Specimen Volume: 2 mL

Specimen Minimum Volume: 1 mL

Collection Instructions: Grossly hemolyzed or lipemic specimen is not acceptable.

Additional Information: Avoid repeated freeze/thaw cycles.

Specimen Transport Temperature

Refrigerate 5 days/Frozen 2 months OK/Ambient NO

Day(s) Test Set Up

Monday through Friday (once daily)

Testing Algorithm

If the Lyme antibody result is positive or equivocal, then Lyme disease antibody confirmation will be performed at an additional charge.

Performing Laboratory

Minnesota
SMDC Clinical Lab (Duluth)

Test Classification and CPT Coding

86618

Reference Values

Negative:  < 0.90

Equivocal:  ≥ 0.90 - < 1.10

Positive:  ≥ 1.10