Sign in →

Test Code LAB5012 Rubella Screen, IgG,  Serum

Additional Codes

Test Name in EPIC EPIC Test Code Mnemonic
RUBELLA SCREEN LAB5012 RUBGG

 

Methodology

Chemiluminescence Immunoassay (CLIA)

Specimen Requirements

Specimen Type: Serum

Container/Tube: Serum gel

Specimen Volume: 0.5 mL

Specimen Minimum Volume: 0.2 mL

Collection Instructions:

1. Grossly hemolyzed, icteric, or lipemic specimens are not acceptable.

2. Separate serum from cells within 2 hours of draw.

3. If plunger filters are used, immediate removal of plasma is indicated unless an air gap can be created between the device and the specimen.

Additional Information:

1. Avoid repeated freeze/thaw cycles.

2. Label specimen appropriately (serum).

 

Specimen Transport Temperature

Refrigerate 5 days/Frozen OK/Ambient 3 days

Day(s) Test Set Up

Monday through Friday 7am to 2pm

Performing Laboratory

Chemistry-

SMDC Clinical Lab

Test Classification and CPT Coding

86762

Reference Values

Non immune: <0.9 IU/mL

Equivocal: 0.9-1.0 IU/mL (Patient should be retested with a new specimen.)