Test Code LABAPCRR Activated Protein C Resistance V, with Reflex to Factor V Leiden, Blood and Plasma
Additional Codes
Test Name in EPIC |
EPIC Test Code | EPIC Mnemonic | Mayo Test ID |
ACTIVATED PROTEIN C RESISTANCE V, REFLEX TO FACTOR V LEIDEN | LABAPCRR | APCRR | APCRR |
Useful For
Evaluating patients with incident or recurrent venous thromboembolism (VTE)
Evaluating individuals with a family history of VTE
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
APCRV | Activated Protein Resistance V, P | Yes | Yes |
SC018 | Whole Blood | No | Yes |
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
F5DNA | Factor V Leiden (R506Q) Mutation, B | Yes | No |
F5DNI | APCRV/F5DNA Summary Interpretation | No | No |
Testing Algorithm
If the assay ratio is abnormal, then factor V Leiden variant analysis will be performed at an additional charge.
When the activated protein C resistance V is abnormal or indeterminate and the factor V Leiden variant assay is performed, a summary interpretation will be provided.
Special Instructions
Method Name
Optical Clot-Based
Reporting Name
APCRV, w/Reflex, PSpecimen Type
Plasma Na CitWhole blood
Necessary Information
Specimen Required
Blood and plasma are required.
Patient Preparation: Fasting preferred
Specimen Type: Whole blood
Container/Tube:
Preferred: Lavender top (EDTA)
Acceptable: Yellow top (ACD) or light-blue top (3.2% sodium citrate)
Specimen Volume: 3 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send whole blood specimen in original tube. Do not aliquot.
Specimen Type: Platelet-poor plasma
Collection Container/Tube: Light-blue top (3.2% sodium citrate)
Submission Container/Tube: Plastic vial, polypropylene preferred
Specimen Volume: 1 mL
Collection Instructions:
1. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.
2. Within 4 hours of collection, centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.
3. Aliquot plasma into separate plastic vial leaving 0.25 mL in the bottom of centrifuged vial.
4. Freeze plasma aliquot immediately at -20° C, or ideally, at -40° C or below.
Additional Information:
1. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Each coagulation assay requested should have its own vial.
Specimen Minimum Volume
Plasma: 0.5 mL; Whole blood: 3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days | |
Whole blood | Ambient (preferred) | 14 days | |
Frozen | 14 days | ||
Refrigerated | 14 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Clinical Information
Protein C, a part of the natural anticoagulant system, is a vitamin K-dependent protein zymogen (molecular weight = 62,000 Da) that is synthesized in the liver and circulates at a plasma concentration of approximately 5 mcg/mL. Protein C is activated to activated protein C (APC) via proteolytic cleavage by thrombin bound to thrombomodulin, an endothelial cell surface membrane protein. APC downregulates the procoagulant system by proteolytically inactivating procoagulant factors Va and VIIIa. Protein S, another vitamin K-dependent coagulation protein, catalyzes APC inactivation of factors Va and VIIIa. APC interacts with and proteolyzes factors V/Va and VIII/VIIIa at specific APC binding and cleavage sites, respectively. Resistance to activated protein C (APC resistance) is a term used to describe abnormal resistance of human plasma to the anticoagulant effects of human APC. APC resistance is characterized by a reduced anticoagulant response of patient plasma after adding a standard amount of APC. For this assay, the activated partial thromboplastin time fails to prolong significantly after the addition of APC.
The vast majority of individuals with familial APC resistance have a specific alteration in the procoagulant factor V gene (F5) encoding for a p.Arg534Gln substitution in the heavy chain of factor V (formerly R506Q). This glutamine to arginine amino acid change alters an APC cleavage site on factor V such that factor V/Va is partially resistant to inactivation by APC. The carrier frequency for the factor V Leiden variant varies depending on the population. Approximately 5% of asymptomatic White Americans of non-Hispanic ancestry are heterozygous carriers. In contrast, the carrier frequency among African Americans, Asian Americans, and Native Americans is less than 1%, and the carrier frequency for Hispanics is intermediate (2.5%). The carrier frequency can be especially high (up to 14%) among White individuals of Northern European or Scandinavian ancestry. Homozygosity for factor V Leiden is much less common but may confer a substantially increased risk for thrombosis. The degree of abnormality of the APC-resistance assay correlates with heterozygosity or homozygosity for the factor V Leiden variant; homozygous carriers have a very low APC-resistance ratio (eg, 1.1-1.4), while the ratio for heterozygous carriers is usually 1.5 to 1.8.
Reference Values
ACTIVATED PROTEIN C RESISTANCE V RATIO
≥2.3
Pediatric reference range has neither been established nor is available in scientific literature. The adult reference range likely would be applicable to children older than 6 months.
Interpretation
An activated protein C (APC) resistance ratio below 2.3 suggests abnormal resistance to APC of hereditary origin.
If the screening APC resistance test is abnormal, DNA-based testing for the factor V Leiden variant (p.Arg534Gln, formerly R506Q) is performed to confirm or exclude hereditary APC-resistance.
Cautions
This assay is highly sensitive and specific for inherited activated protein C (APC) resistance, most commonly due to the factor V Leiden variant, but will not detect patients with acquired APC resistance. Persons with acquired APC resistance are at similar risk for venous thromboembolism.
Preanalytical conditions of the patient and the blood specimen are extremely important for reliable performance and interpretation of testing for APC resistance. Plasma specimens demonstrating prolongation of clotting times (prothrombin time, activated partial thromboplastin time) for reasons other than anticoagulant effects (eg, lupus-like anticoagulants or specific coagulation factor inhibitors) generally cannot be reliably tested for the presence or absence of APC resistance. Proper preparation of the plasma specimen is extremely important to help ensure accuracy of results and interpretation.
This assay has greater than 99% sensitivity for detecting the presence of the factor V Leiden variant. Discrepant results of plasma-based activated protein C resistance ratio (APCRV) and DNA-based factor V Leiden testing may occur in recipients of liver or allogeneic hematopoietic stem cell transplants, or due to anticoagulant effects, such as excess heparin, direct thrombin inhibitors argatroban (Acova), bivalirudin (Angiomax) or dabigatran (Pradaxa); or direct factor Xa inhibitors rivaroxaban (Xarelto), apixaban (Eliquis), and edoxaban (Savaysa); or a sample mix up. Suggest clinical correlation. If DNA-based testing for the factor V Leiden variant is clinically indicated, call 800-533-1710.
Although the APC-resistance assay can be performed in the absence of other coagulation tests and clinical information, it is most reliably performed as part of a consultative coagulation test panel with interpretive reporting (including appropriate testing of the same specimen to evaluate for the presence or absence of coagulation abnormalities or conditions that may affect interpretation of the APC-resistance assay). This test is included among a panel of tests; see AATHR / Thrombophilia Profile, Plasma and Whole Blood.
Method Description
This assay is performed using the HemosIL Factor V Leiden (APC Resistance V) Kit on the Instrumentation Laboratory ACL TOP instrument. The method uses a modified activated partial thromboplastin time (aPTT) test to detect activated protein C (APC) resistance. The plasma specimen is prediluted in factor V-deficient plasma. Then the aPTT test is performed by incubating patient plasma with a standardized amount of platelet-like phospholipids and activator of the contact factors of the intrinsic coagulation pathway, followed by recalcification of plasma and measurement of clotting time. The ratio of the aPTT test with and without added APC is reported as the APC resistance (or sensitivity) ratio.(Package insert: HemosIL Factor V Leiden [APC Resistance V]. Instrumentation Laboratory Company; Rev 11/2017)
Day(s) Performed
Monday through Friday
Report Available
4 to 7 daysSpecimen Retention Time
Plasma: 7 days: Whole blood: 2 weeksPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
85307
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
APCRR | APCRV, w/Reflex, P | 13590-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
APCR | APCRV Ratio | 13590-5 |
SC018 | Whole Blood | No LOINC Needed |
INT55 | Interpretation | 48591-2 |
Forms
1. New York Clients-Informed consent is required. Document on the request form or electronic order that a copy is on file. The following documents are available:
-Informed Consent for Genetic Testing (T576)
-Informed Consent for Genetic Testing-Spanish (T826)
2. Coagulation Patient Information (T675)
3. If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.