Test Code LABBUPR Buprenorphine Screen with Reflex, Random, Urine
Additional Codes
Test Name in EPIC | EPIC Test Code | Mnemonic | Mayo Test ID |
---|---|---|---|
BUPRENORPHINE SCREEN WITH REFLEX, URINE | LABBUPR | BUPR | BUPR |
Useful For
Screening and confirmation for drug abuse or use of buprenorphine
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
BUPS | Buprenorphine Screen, U | Yes | Yes |
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
BUPM | Buprenorphine and Metabolite, U | Yes | No |
Testing Algorithm
Testing begins with a screening assay. If the buprenorphine screen is positive, then the liquid chromatography tandem mass spectrometry confirmation with quantification will be performed at an additional charge.
Method Name
Immunoassay
Reporting Name
Buprenorphine Screen w/Reflex, USpecimen Type
UrineOrdering Guidance
For screening buprenorphine alone, order BUPS / Buprenorphine Screen, Random, Urine.
For comprehensive opioid screening, order TOSU / Targeted Opioid Screen, Random, Urine.
For situations where chain of custody is required, a Chain of Custody Kit (T282) is available. For chain-of-custody testing, order BUPMX / Buprenorphine and Norbuprenorphine, Chain of Custody, Random, Urine.
Additional Testing Requirements
If urine creatinine is required or adulteration of the sample is suspected, the following test should also be ordered, ADULT / Adulterants Survey, Random, Urine.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Plastic urine container
Submission Container/Tube: Plastic vial
Specimen Volume: 5 mL
Collection Instructions:
1. Collect a random urine specimen.
2. Submit 5 mL in 1 plastic vial.
3. No preservative.
Additional Information:
1. No specimen substitutions.
2. STAT requests are not accepted for this test.
3. Submitting less than 5 mL will compromise the ability to perform all necessary testing.
Specimen Minimum Volume
2.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 14 days | |
Frozen | 14 days | ||
Ambient | 72 hours |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Clinically, buprenorphine is utilized as a substitution therapy for opioid dependence and as an analgesic. Buprenorphine is a partial agonist of the mu-opioid receptor. These mu binding sites are discretely distributed in the human brain, spinal cord, and other tissue. The clinical effects of mu receptor agonists are sedation, euphoria, respiratory depression, and analgesia. As a partial mu receptor agonist, buprenorphine's clinical effects are decreased, giving buprenorphine a wider safety margin.(1) Buprenorphine has a prolonged duration of activity. The combination of decreased clinical effects and prolonged activity gives buprenorphine the added advantage of a delayed and decreased withdrawal syndrome, compared to other opioids.(1) Compared to morphine, buprenorphine is 25 to 40 times more potent.(1) As with any opioid, abuse is always a concern. To reduce illicit use of buprenorphine, it is available mixed with naloxone in a ratio of 4:1. When the combination is taken as prescribed, only small amounts of naloxone will be absorbed. However, if the combination is transformed into the injectable form, naloxone then acts as an opioid receptor antagonist.
Buprenorphine is metabolized through N-dealkylation to norbuprenorphine through cytochrome P450 3A4 (CYP 3A4). Both parent and metabolite then undergo glucuronidation. Norbuprenorphine is an active metabolite possessing one fifth of the potency of its parent. The glucuronide metabolites are inactive.(1)
This procedure uses immunoassay reagents that are designed to produce a negative result when no drugs are present in a natural (ie, unadulterated) specimen of urine; the assay is designed to have a high true-negative rate. Like all immunoassays, it can produce a false-positive result due to cross-reactivity with natural chemicals and drugs other than those they were designed to detect. The immunoassay also can produce a false-negative result due to the antibody's ability to cross-react with different drugs in the target class.
Reference Values
Negative
Screening cutoff concentration:
Buprenorphine: 5 ng/mL
Interpretation
If the screen result is negative, buprenorphine concentrations were not detected.
If the screen result is positive, then confirmation by liquid chromatography tandem mass spectrometry will be performed.
A positive interpretation will be given if either the buprenorphine result is greater than or equal to 5.0 ng/mL or the norbuprenorphine result is greater than or equal to 2.5 ng/mL.
The presence of buprenorphine above 5.0 ng/mL or norbuprenorphine above 2.5 ng/mL is a strong indicator that the patient has used buprenorphine.
Cautions
Care should be taken when interpreting results since there are many factors (eg, fluid intake and other biologic factors) that may influence a urine test result. It is possible that substances other than those investigated in the specificity study may interfere with the test and cause false-positive or false-negative results.
Method Description
This assay is a homogeneous enzyme immunoassay technique. The assay will be performed semi-quantitatively. The assay is based on competition between free drug in the urine sample, and a drug labeled with the enzyme glucose-6-phosphate dehydrogenase for a fixed amount of specific antibody binding sites. Active enzyme reduces nicotinamide adenine dinucleotide (NAD[+]) to NADH, which results in an absorbance change that can be measured spectrophotometrically at 340nm. Similar testing is being performed on the Olympus AU680 analyzer and this test would be an addition to the current testing.(Package insert: Buprenorphine Urine Enzyme Immunoassay. Immunalysis Corporation; 04/2021)
Day(s) Performed
Monday through Saturday
Report Available
Same day/1 to 2 daysSpecimen Retention Time
14 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80307
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
BUPR | Buprenorphine Screen w/Reflex, U | 93494-3 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
63119 | Buprenorphine Screen, U | 93494-3 |
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.