Test Code LABHHV6AB Human Herpesvirus 6 (HHV-6A and HHV-6B) by Quantitative PCR
Additional Codes
Test Name in EPIC | EPIC Test Code | Mnemonic | ARUP Test ID |
---|---|---|---|
Human Herpesvirus 6(HHV-6A,HHV-6B) Quant PCR | LABHHV6AB | HHV6PCR | 0060071 |
Useful For/Utility
Detect and quantify HHV6 subtypes A and B in immunocompromised patients.
Methodology
Quantitative Polymerase Chain Reaction
Specimen Requirements
Collect
Lavender (EDTA), pink (K2EDTA), serum separator tube, or CSF.
Specimen Preparation
Separate serum or plasma from cells. Transfer 1 mL serum, plasma or CSF to a sterile container. (Min: 0.5 mL)
Unacceptable Conditions
Heparinized specimens, tissues in optimal cutting temperature compound.
Remarks
Specimen source required.
Specimen Transport Temperature
Storage/Transport Temperature
Frozen.
Test Classification and CPT Coding
87533
LOINC
HHV6 by PCR Source 31208-2
HHV6 by PCR Type 38348-9
HHV6 Quant by PCR (copy/mL) 38349-7
HHV6 Quant by PCR (log copy/mL) 38350-5
HHV6 by PCR Interp 51730-0
HHV6 Quant by PCR (log IU/mL) 100680-8
HHV6 Quant by PCR (IU/mL) 101255-8
Day(s) Performed
Tues-Sat
Reported 1-4 days
Reference Values
Not detected
Interpretation
The quantitative range of this assay is 2.7-6.7 log copies/mL (500-5,000,000 copies/mL) or 3.1-7.1 log IU/mL (1250-12,500,000 IU/mL).
1 copies/mL is approximately 2.5 IU/mL.
A negative result (less than 2.7 log copies/mL or less than 500 copies/mL; less than 3.1 log IU/mL or less than 1250 IU/mL) does not rule out the presence of PCR inhibitors in the patient specimen or HHV6 DNA in concentrations below the level of detection of the assay. Inhibition may also lead to underestimation of viral quantitation.
The limit of quantification for this DNA assay is 2.7 log copies/mL (500 copies/mL) or 3.1 log IU/mL (1250 IU/mL). If the assay DID NOT DETECT the virus, the test result will be reported as "<2.7 log copies/mL (<500 copies/mL). and <3.1 log IU/mL (<1250 IU/mL)." If the assay DETECTED the presence of the virus but was not able to accurately quantify the number of copies, the test result will be reported as "Not Quantified."
This assay detects and quantifies HHV6 subtypes A and B.