Sign in →

Test Code LABLURASID Lurasidone Quantitative

Additional Codes

Test Name in EPIC

EPIC Test Code

Mnemonic

Lurasidone Quantitative LABLURASID LURASID

 

Specimen Requirements

Plain Red (no Gel); Purple top EDTA

Separate from cells ASAP or within 2 hours of collection. Transfer 1 mL serum or plasma to an ARUP Standard Transport Tube. (Min: 0.3 mL)

Specimen Transport Temperature

Refrigerated

Performing Laboratory

ARUP forward to NMS Labs, Inc.

200 Welsh Road

Horsham, PA 19044-2208

Test Classification and CPT Coding

Component Test Code* Component Chart Name  LOINC
2013019 Lurasidone Quantitative, Serum/Plasma 93437-2

 

Reference Values

Reporting Limit:  2.5 ng/mL

Useful For/Usage

Optimize drug therapy and monitor patient adherence.

Methodology

Quantitative High Performance Liquid Chromatography/Tandem Mass Spectrometry