Sign in →

Test Code LABRIBP Ribosome P Antibodies, IgG, Serum

Additional Codes

 

Test Name in EPIC EPIC Test Code Mnemonic Mayo Test ID
RIBOSOME P AB, S LABRIBP RIB RIB

 

Reporting Name

Ribosome P Ab, IgG, S

Useful For

As an adjunct in the diagnostic evaluation of patients with systemic lupus erythematosus (SLE)

 

May be useful in the phenotypic stratification of SLE patients at risk for neuropsychiatric SLE, lupus nephritis and/or hepatitis

Testing Algorithm

For more information see Connective Tissue Disease Cascade.

Method Name

Multiplex Flow Immunoassay

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.35 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK
Heat-Treated Reject

Special Instructions

Reference Values

<1.0 U (negative)

≥1.0 U (positive)

Reference values apply to all ages.

Day(s) Performed

Monday through Saturday

CPT Code Information

83516

LOINC Code Information

Test ID Test Order Name Order LOINC Value
RIB Ribosome P Ab, IgG, S 53892-6

 

Result ID Test Result Name Result LOINC Value
RIB Ribosome P Ab, IgG, S 53892-6

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

Clinical Information

Systemic lupus erythematosus (SLE) is a heterogeneous autoimmune disease that affects multiple organ systems with diverse clinical presentations. The disease is characterized by a diversity of antinuclear antibody (ANA) specificities associated with positivity of nuclear and/or cytoplasmic patterns using the HEp-2 substrate by indirect immunofluorescence assay (IFA).(1,2) Of the ANA-specific autoantibodies, only anti-dsDNA and anti-Smith antibodies associated with the Hep-2 substrate IFA nuclear patterns are required in contemporary classification criteria for SLE.(3,4) Detection of non-criteria SLE autoantibodies and their associated  profiles are fundamental in the clinical management of patients as these antibodies provide important clues for diagnosis, phenotypic categorization, and disease activity, as well as potential therapeutic targets.(5) For example, these autoantibodies may be involved in the inflammatory and immune complex formation causing damage in multiple end-organs such as kidney, skin, and central nervous system (CNS).

 

Anti-ribosomal P protein (anti-Rib-P, anti-P) antibodies were initially described in the 1980s and subsequently reported to recognize three specific ribosomal proteins (P0, P1 and P2, of 38, 19 and 17 kDa molecular weight, respectively) located in the large ribosome's subunit.(6).  A 2015 systematic review and meta-analysis of published studies reported significant association with malar rash, oral ulcer, photosensitivity and anti-dsDNA antibody positivity.(7) However, the associations with neuropsychiatric SLE, hepatic damage, serum anti-Smith and anti-cardiolipin antibodies were observed more frequently in anti-Rib-P positive patients than in negative patients. In a more recent meta-analysis, significant associations were noted for CNS involvement and psychosis, and lupus hepatitis with heterogeneity between studies for lupus nephritis.(6)  In a recent large single center study, anti-Rib-P antibody positivity was associated with a higher proportion of neurological involvement (p <0.05) at baseline.(8) In the same study, antibody-positive patients for anti-Rib-P antibodies were more likely to accumulate neuropsychiatric damage (adjusted HR = 3.8, 95% CI 2.7-57), p <0.001). The variable clinical associations between positivity for anti-Rib-P antibodies and the reported SLE manifestations in these and other studies may be due to demographic and clinical heterogeneity of the cohorts and different formulations of the immunoassays and methods for detecting antibodies.(6,9)

 

Anti-ribosomal antibodies can be detected and quantified using a variety solid-phase immunoassays in the clinical laboratory. The use of different antigenic combinations and antigens from different sources limit commutability between testing methods.(6)

Interpretation

As an adjunct in the diagnostic evaluation of patients with systemic lupus erythematosus (SLE)

 

May be useful in the phenotypic stratification of SLE patients at risk for neuropsychiatric SLE, lupus nephritis and/or hepatitis

Cautions

Most patients with systemic lupus erythematosus (SLE) do not have detectable levels of antibodies to ribosome P protein.

 

Positivity of anti-ribosomal p antibody alone should not be relied upon to establish the diagnosis or to rule out the diagnosis in a patient with signs and symptoms compatible with SLE.

Method Description

Affinity-purified ribosome P antigens are coupled covalently to polystyrene microspheres, which are impregnated with fluorescent dyes to create a unique fluorescent signature. Ribosome P antibodies, if present in diluted serum, bind to ribosome P antigen on the microspheres. The microspheres are washed to remove extraneous serum proteins. Phycoerythrin (PE)-conjugated, antihuman IgG antibody is then added to detect IgG anti-ribosome P antibodies bound to the microspheres. The microspheres are washed to remove unbound conjugate, and bound conjugate is detected by laser photometry. A primary laser reveals the fluorescent signature of each microsphere to distinguish it from microspheres that are labeled with other antigens, and a secondary laser reveals the level of PE fluorescence associated with each microsphere. Results are calculated by comparing the median fluorescence response for ribosome P microspheres to a 4-point calibration curve.(Package insert: Bioplex 2200 ANA Screen. Bio-Rad Laboratories; 02/2019)

Report Available

Same day/1 to 3 days

Specimen Retention Time

14 days