Test Code LABRIBP Ribosome P Antibodies, IgG, Serum
Additional Codes
Test Name in EPIC | EPIC Test Code | Mnemonic | Mayo Test ID |
---|---|---|---|
RIBOSOME P AB, S | LABRIBP | RIB | RIB |
Reporting Name
Ribosome P Ab, IgG, SUseful For
As an adjunct in the diagnostic evaluation of patients with systemic lupus erythematosus (SLE)
May be useful in the phenotypic stratification of SLE patients at risk for neuropsychiatric SLE, lupus nephritis and/or hepatitis
Testing Algorithm
For more information see Connective Tissue Disease Cascade.
Method Name
Multiplex Flow Immunoassay
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumSpecimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.35 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 21 days | |
Frozen | 21 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | OK |
Heat-Treated | Reject |
Special Instructions
Reference Values
<1.0 U (negative)
≥1.0 U (positive)
Reference values apply to all ages.
Day(s) Performed
Monday through Saturday
CPT Code Information
83516
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
RIB | Ribosome P Ab, IgG, S | 53892-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
RIB | Ribosome P Ab, IgG, S | 53892-6 |
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.Clinical Information
Systemic lupus erythematosus (SLE) is a heterogeneous autoimmune disease that affects multiple organ systems with diverse clinical presentations. The disease is characterized by a diversity of antinuclear antibody (ANA) specificities associated with positivity of nuclear and/or cytoplasmic patterns using the HEp-2 substrate by indirect immunofluorescence assay (IFA).(1,2) Of the ANA-specific autoantibodies, only anti-dsDNA and anti-Smith antibodies associated with the Hep-2 substrate IFA nuclear patterns are required in contemporary classification criteria for SLE.(3,4) Detection of non-criteria SLE autoantibodies and their associated profiles are fundamental in the clinical management of patients as these antibodies provide important clues for diagnosis, phenotypic categorization, and disease activity, as well as potential therapeutic targets.(5) For example, these autoantibodies may be involved in the inflammatory and immune complex formation causing damage in multiple end-organs such as kidney, skin, and central nervous system (CNS).
Anti-ribosomal P protein (anti-Rib-P, anti-P) antibodies were initially described in the 1980s and subsequently reported to recognize three specific ribosomal proteins (P0, P1 and P2, of 38, 19 and 17 kDa molecular weight, respectively) located in the large ribosome's subunit.(6). A 2015 systematic review and meta-analysis of published studies reported significant association with malar rash, oral ulcer, photosensitivity and anti-dsDNA antibody positivity.(7) However, the associations with neuropsychiatric SLE, hepatic damage, serum anti-Smith and anti-cardiolipin antibodies were observed more frequently in anti-Rib-P positive patients than in negative patients. In a more recent meta-analysis, significant associations were noted for CNS involvement and psychosis, and lupus hepatitis with heterogeneity between studies for lupus nephritis.(6) In a recent large single center study, anti-Rib-P antibody positivity was associated with a higher proportion of neurological involvement (p <0.05) at baseline.(8) In the same study, antibody-positive patients for anti-Rib-P antibodies were more likely to accumulate neuropsychiatric damage (adjusted HR = 3.8, 95% CI 2.7-57), p <0.001). The variable clinical associations between positivity for anti-Rib-P antibodies and the reported SLE manifestations in these and other studies may be due to demographic and clinical heterogeneity of the cohorts and different formulations of the immunoassays and methods for detecting antibodies.(6,9)
Anti-ribosomal antibodies can be detected and quantified using a variety solid-phase immunoassays in the clinical laboratory. The use of different antigenic combinations and antigens from different sources limit commutability between testing methods.(6)
Interpretation
As an adjunct in the diagnostic evaluation of patients with systemic lupus erythematosus (SLE)
May be useful in the phenotypic stratification of SLE patients at risk for neuropsychiatric SLE, lupus nephritis and/or hepatitis
Cautions
Most patients with systemic lupus erythematosus (SLE) do not have detectable levels of antibodies to ribosome P protein.
Positivity of anti-ribosomal p antibody alone should not be relied upon to establish the diagnosis or to rule out the diagnosis in a patient with signs and symptoms compatible with SLE.
Method Description
Affinity-purified ribosome P antigens are coupled covalently to polystyrene microspheres, which are impregnated with fluorescent dyes to create a unique fluorescent signature. Ribosome P antibodies, if present in diluted serum, bind to ribosome P antigen on the microspheres. The microspheres are washed to remove extraneous serum proteins. Phycoerythrin (PE)-conjugated, antihuman IgG antibody is then added to detect IgG anti-ribosome P antibodies bound to the microspheres. The microspheres are washed to remove unbound conjugate, and bound conjugate is detected by laser photometry. A primary laser reveals the fluorescent signature of each microsphere to distinguish it from microspheres that are labeled with other antigens, and a secondary laser reveals the level of PE fluorescence associated with each microsphere. Results are calculated by comparing the median fluorescence response for ribosome P microspheres to a 4-point calibration curve.(Package insert: Bioplex 2200 ANA Screen. Bio-Rad Laboratories; 02/2019)