Test Code LABSYNOVASURE Periprosthetic Joint Infection Detection (SYNOVASURE)
Additional Codes
Test Name in EPIC | EPIC Test Code | Mnemonic | CD LaboratoriesTest ID |
---|---|---|---|
PERIPROSTHETIC JOINT INFECTION DETECTION (SYNOVASURE) | LABSYNOVASURE | SYNOVASURE | Synovasure Comprehensive PJI Test Panel |
Methodology
Qualitative Enzyme-Linked Immunosorbent Assay
Specimen Requirements
2- 2 mL Clear top Red Stopper and 1 Purple top EDTA tubes from Synovasure Kit. - Aspirate joint using standard technique* -Verify tubes are within expiration date. -Transfer fluid to tubes. Specimen volume and tube detail requirements listed on reverse side. *Ensure that specimen is not diluted at time of aspiration by saline lavage, contrast, blood or other non-synovial fluids. |
Collection instructions located under the resources section to the left.
Specimen Transport Temperature
Monday – Friday
- Collect and ship same day as aspiration. Store at an ambient
temperature.
Saturday – Sunday
- Collect specimen and store in refrigeration (2-8°C). Ship on Monday.
Note: For best results, specimens should ship the same day as collected
Performing Laboratory
CDL Reference Lab/ Zimer Biomedical
Test Classification and CPT Coding
IMMUNOASSAY - REF [83516] |
1 |
|
C-REACTIVE PROTEIN - REF [86140] |
Additional charges may be applied for any reflex testing
Report Available
3-4 days